CVE-2016-8369

An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application does not sufficiently verify if a request was intentionally provided by the user who submitted the request (CROSS-SITE REQUEST FORGERY).

CVE-2016-8370

An issue was discovered in Mitsubishi Electric Automation MELSEC-Q series Ethernet interface modules QJ71E71-100, all versions, QJ71E71-B5, all versions, and QJ71E71-B2, all versions. Weakly encrypted passwords are transmitted to a MELSEC-Q PLC.

CVE-2016-8372

An issue was discovered in Moxa ioLogik E1210, firmware Version V2.4 and prior, ioLogik E1211, firmware Version V2.3 and prior, ioLogik E1212, firmware Version V2.4 and prior, ioLogik E1213, firmware Version V2.5 and prior, ioLogik E1214, firmware Version V2.4 and prior, ioLogik E1240, firmware Version V2.3 and prior, ioLogik E1241, firmware Version V2.4 and prior, ioLogik E1242, firmware Version V2.4 and prior, ioLogik E1260, firmware Version V2.4 and prior, ioLogik E1262, firmware Version V2.4 and prior, ioLogik E2210, firmware versions prior to V3.13, ioLogik E2212, firmware versions prior to V3.14, ioLogik E2214, firmware versions prior to V3.12, ioLogik E2240, firmware versions prior to V3.12, ioLogik E2242, firmware versions prior to V3.12, ioLogik E2260, firmware versions prior to V3.13, and ioLogik E2262, firmware versions prior to V3.12. A password is transmitted in a format that is not sufficiently secure.

CVE-2016-8378

An issue was discovered in Lynxspring JENEsys BAS Bridge versions 1.1.8 and older. The application’s database lacks sufficient safeguards for protecting credentials.

CVE-2016-9347

An issue was discovered in Emerson SE4801T0X Redundant Wireless I/O Card V13.3, and SE4801T1X Simplex Wireless I/O Card V13.3. DeltaV Wireless I/O Cards (WIOC) running the firmware available in the DeltaV system, release v13.3, have the SSH (Secure Shell) functionality enabled unnecessarily.

CVE-2016-9354

An issue was discovered in Moxa DACenter Versions 1.4 and older. A specially crafted project file may cause the program to crash because of Uncontrolled Resource Consumption.

CVE-2016-8566

An issue was discovered in Siemens SICAM PAS before 8.00. Because of Storing Passwords in a Recoverable Format, an authenticated local attacker with certain privileges could possibly reconstruct the passwords of users for accessing the database.

CVE-2016-9353

An issue was discovered in Advantech SUISAccess Server Version 3.0 and prior. The admin password is stored in the system and is encrypted with a static key hard-coded in the program. Attackers could reverse the admin account password for use.

CVE-2016-9338

An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. Because of an Incorrect Permission Assignment for Critical Resource, users with administrator privileges may be able to remove all administrative users requiring a factory reset to restore ancillary web server function. Exploitation of this vulnerability will still allow the affected device to function in its capacity as a controller.